Precision Flow Meters P000 / P210 series detector

flowmeter
Car/Construction/Farm machine etc. The highly precise fuel flowmeter that is ideal for energy-saving measures, Positive type 4-radial piston type
A series of highly accurate fuel flowmeters is ideal for energy saving measures.
A fuel flowmeter detects a flow rate by an “unparalleled” original Hall element sensor.
It has a built-in CPU circuit, whereby high-speed response, high resolution, the highest accuracy and high reproducibility are realized by various software functions in a wide range of flow rates.
An environment that is optimal for fuel injection flow-rate measurement and fuel-economy measurement of various engines is provided as a flowmeter system.

Model List

Micro Flow Meter Standard type MODEL P213/295F

Micro Flow Meter Standard type MODEL P213/295F
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating biggest pressure 7MPa/21MPa(52.5MPa option)
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
The smallest resolution 0.001mL(0.001cc/pulses) at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc , or A phase/B phase each 500pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The engine fuel consumption measurement,
The exhaust fluid measurement, Valve leak examination etc.

Micro Flow Meter High pressure type MODEL P002F

Micro Flow Meter High pressure type MODEL P002F
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 52.5MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.001mL(0.001cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The engine fuel consumption measurement
Lubricating oil for industrial equipment and fuel flow quantity.

Super Micro Flow Meter High pressure type MODEL P001F

Super Micro Flow Meter High pressure type MODEL P001F
Flow range 0.005 to 200cc/min(0.0003 to 12L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 50Mpa
Operating Temperature -40 to 90℃(-40 to 155℃ /225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.00008mL(0.00008cc/pulses)
Pulse Transmitter Single phase 12000pulses/cc, or A phase/B phase each 12000pulses
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use Gasoline direct jet discharge measurement,
The drone machine mileage measurement,
Bubble leak examination etc.

Micro Flow Meter Super high temperature type MODEL P213/295FT

Micro Flow Meter Super high temperature type MODEL P213/295FT
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa
Operating Temperature -40 to 155℃/225℃(The measurement output part separates.)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.001mL(0.001cc/pulses) at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc ,or A phase/B phase each 500pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols
Main use The engine fuel consumption measurement,
The quantity of chemicals infusion measurement,
The measurement of the odorant etc.

Micro Flow Meter Explosion proof type MODEL P213/EX295F

Micro Flow Meter Explosion proof type MODEL P213/EX295F
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa(52.5MPa option)
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.001mL(0.001cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The engine fuel consumption measurement,
The quantity of chemicals infusion measurement,
The measurement of the odorant etc.

Micro Flow Rate Meter Associate system type MODEL P213/295FS

Micro Flow Rate Meter Associate system type MODEL P213/295FS
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa(52.5MPa option)
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.001mL(0.001cc/pulses) at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc
Fuel filter Stainless steel MODEL 381(element 10micron)
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The engine fuel consumption measurement,
The exhaust fluid measurement, Valve leak examination etc.

Micro Flow Meter High pressure system type MODEL P213/295FSP

Micro Flow Meter High pressure system type MODEL P213/295FSP
Flow range 0.5 to 1800cc/min(0.03 to 108L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.001mL(0.001cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The engine fuel consumption measurement,
The exhaust fluid measurement, Valve leak examination etc.

Micro/Middle Flow Meter Standard type MODEL P214/295F

Micro/Middle Flow Meter Standard type MODEL P214/295F
Flow range 0.005 to 10L/min(0.3 to 600L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa(52.5MPa option)
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.01mL(0.01cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use The plane hydraulic fluid measurement, The measurement of
the hydraulic fluid of the heavy industrial machine and the fuel consumption etc.

Micro/Middle Flow Meter High pressure type MODEL P214-591/295FP

Micro/Middle Flow Meter High pressure type MODEL P214-591/295FP
Flow range 0.005 to 10L/min(0.3~600L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 52.5MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.01mL(0.01cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use Odorant infusion, The quantity of chemicals infusion measurement,
The aviation hydraulic fluid bare measurement etc.

Micro/Middle Flow Meter Explosion proof type MODEL P214/EX295F

Micro/Middle Flow Meter Explosion proof type MODEL P214/EX295F
Flow range 0.05 to 10L/min(0.3 to 600L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.01mL(0.01cc/pulses)at the single phase pulse
Pulse Transmitter Single phase 90pulses/cc , or A phase/B phase each 45pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use Odorant infusion, The quantity of chemicals infusion measurement,
The aviation hydraulic fluid bare measurement etc.

Micro/Middle Flow Meter System standard type MODEL P214/295FS

Micro/Middle Flow Meter System standard type MODEL P214/295FS
Flow range 0.005 to 10L/min(0.3~600L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.01mL(0.01cc/pulses) at the single phase pulse
Pulse Transmitter Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use Odorant infusion, The quantity of chemicals infusion measurement,
The aviation hydraulic fluid bare measurement etc.

High Flow Meter Standard type MODEL P215/295F

High Flow Meter Standard type MODEL P215/295F
Flow range 0.05 to 35L/min(3 to 2100L/h)
Accuracy ±0.2% of reading over a 200:1 range
(16point linearization precision revision)
Reproducibility less than ±0.1%
Operating Pressure 7MPa/21MPa
Operating Temperature -40 to 90℃(-40 to 155℃/225℃ option)
Use fluid viscosity 0.5 to 1000cps
Smallest resolution 0.05mL(0.05cc/pulses) at the single phase pulse
Pulse Transmitter Single phase 20000pulses/L , or A phase/B phase each 10000pulses/L
Available Fluid Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc.
Main use Marine application large size engine discharge measurement
The plane hydraulic fluid measurement etc.

Fuel filter Standard type MODEL 381

Fuel filter Standard type MODEL 381
Stainless steel filter structure part materials
Body
: SUS303, Seals(O rings)Viton®
Element
: SUS316 (reusable by washing)
Element size 10micron(5,30,100micron option)
Use biggest pressure 10.5MPa
Connection port 3/8NPT
Outside dimension/Weight W35×H41.3×63.5 0.8kg