- Car/Construction/Farm machine etc. The highly precise fuel flowmeter that is ideal for energy-saving measures, Positive type 4-radial piston typeA series of highly accurate fuel flowmeters is ideal for energy saving measures.
A fuel flowmeter detects a flow rate by an “unparalleled” original Hall element sensor.
It has a built-in CPU circuit, whereby high-speed response, high resolution, the highest accuracy and high reproducibility are realized by various software functions in a wide range of flow rates.
An environment that is optimal for fuel injection flow-rate measurement and fuel-economy measurement of various engines is provided as a flowmeter system.
Model List
Micro Flow Meter Standard type MODEL P213/295F
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating biggest pressure | 7MPa/21MPa(52.5MPa option) |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
The smallest resolution | 0.001mL(0.001cc/pulses) at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc , or A phase/B phase each 500pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The engine fuel consumption measurement, The exhaust fluid measurement, Valve leak examination etc. |
Micro Flow Meter High pressure type MODEL P002F
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 52.5MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.001mL(0.001cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The engine fuel consumption measurement Lubricating oil for industrial equipment and fuel flow quantity. |
Super Micro Flow Meter High pressure type MODEL P001F
Flow range | 0.005 to 200cc/min(0.0003 to 12L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 50Mpa |
Operating Temperature | -40 to 90℃(-40 to 155℃ /225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.00008mL(0.00008cc/pulses) |
Pulse Transmitter | Single phase 12000pulses/cc, or A phase/B phase each 12000pulses |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | Gasoline direct jet discharge measurement, The drone machine mileage measurement, Bubble leak examination etc. |
Micro Flow Meter Super high temperature type MODEL P213/295FT
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa |
Operating Temperature | -40 to 155℃/225℃(The measurement output part separates.) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.001mL(0.001cc/pulses) at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc ,or A phase/B phase each 500pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols |
Main use | The engine fuel consumption measurement, The quantity of chemicals infusion measurement, The measurement of the odorant etc. |
Micro Flow Meter Explosion proof type MODEL P213/EX295F
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa(52.5MPa option) |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.001mL(0.001cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The engine fuel consumption measurement, The quantity of chemicals infusion measurement, The measurement of the odorant etc. |
Micro Flow Rate Meter Associate system type MODEL P213/295FS
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa(52.5MPa option) |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.001mL(0.001cc/pulses) at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc |
Fuel filter | Stainless steel MODEL 381(element 10micron) |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The engine fuel consumption measurement, The exhaust fluid measurement, Valve leak examination etc. |
Micro Flow Meter High pressure system type MODEL P213/295FSP
Flow range | 0.5 to 1800cc/min(0.03 to 108L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.001mL(0.001cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 1000pulses/cc, or A phase/B phase each 500pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The engine fuel consumption measurement, The exhaust fluid measurement, Valve leak examination etc. |
Micro/Middle Flow Meter Standard type MODEL P214/295F
Flow range | 0.005 to 10L/min(0.3 to 600L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa(52.5MPa option) |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.01mL(0.01cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | The plane hydraulic fluid measurement, The measurement of the hydraulic fluid of the heavy industrial machine and the fuel consumption etc. |
Micro/Middle Flow Meter High pressure type MODEL P214-591/295FP
Flow range | 0.005 to 10L/min(0.3~600L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 52.5MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.01mL(0.01cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | Odorant infusion, The quantity of chemicals infusion measurement, The aviation hydraulic fluid bare measurement etc. |
Micro/Middle Flow Meter Explosion proof type MODEL P214/EX295F
Flow range | 0.05 to 10L/min(0.3 to 600L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.01mL(0.01cc/pulses)at the single phase pulse |
Pulse Transmitter | Single phase 90pulses/cc , or A phase/B phase each 45pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | Odorant infusion, The quantity of chemicals infusion measurement, The aviation hydraulic fluid bare measurement etc. |
Micro/Middle Flow Meter System standard type MODEL P214/295FS
Flow range | 0.005 to 10L/min(0.3~600L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.01mL(0.01cc/pulses) at the single phase pulse |
Pulse Transmitter | Single phase 90pulses/cc, or A phase/B phase each 45pulses/cc |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | Odorant infusion, The quantity of chemicals infusion measurement, The aviation hydraulic fluid bare measurement etc. |
High Flow Meter Standard type MODEL P215/295F
Flow range | 0.05 to 35L/min(3 to 2100L/h) |
---|---|
Accuracy | ±0.2% of reading over a 200:1 range (16point linearization precision revision) |
Reproducibility | less than ±0.1% |
Operating Pressure | 7MPa/21MPa |
Operating Temperature | -40 to 90℃(-40 to 155℃/225℃ option) |
Use fluid viscosity | 0.5 to 1000cps |
Smallest resolution | 0.05mL(0.05cc/pulses) at the single phase pulse |
Pulse Transmitter | Single phase 20000pulses/L , or A phase/B phase each 10000pulses/L |
Available Fluid | Gasoline, Light oil, Heavy oil, Lubricating oil, Alcohols etc. |
Main use | Marine application large size engine discharge measurement The plane hydraulic fluid measurement etc. |
Fuel filter Standard type MODEL 381
Stainless steel filter structure part materials |
|
---|---|
Element size | 10micron(5,30,100micron option) |
Use biggest pressure | 10.5MPa |
Connection port | 3/8NPT |
Outside dimension/Weight | W35×H41.3×63.5 0.8kg |